BPQFJ - E61 R25, STRUCTURAL STEEL SHOP COAT PRIMER
- MSDS: BPQFJ
- Manufacturer: SHERWIN WILLIAMS CO
- Product Name: E61 R25, STRUCTURAL STEEL SHOP COAT PRIMER
- National Stock Number: 8010-00N033258
Product Identification
Product ID:E61 R25, STRUCTURAL STEEL SHOP COAT PRIMER
MSDS Date:12/20/1986
FSC:8010
NIIN:00N033258
MSDS Number: BPQFJ
Responsible Party
CLEVELAND, OH 44115
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
12
CAS: 64742-48-9
Fraction By Weight: 15%
ACGIH TLV: 300 PPM (MFR)
2
CAS: 64742-47-8
Fraction By Weight: 30%
OSHA PEL 500 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
CHROMATE (1-), HYDROXYOCTAOXODIZINCATEDI-, POTASSIUM;
CAS: 11103-86-9
RTECS: GA9170000
Fraction By Weight: <5%
ACGIH TLV: 0.05 MG/M3 (MFR)
TURN OFF STOVES, ELEC TOOLS/APPLIANCES & ANY
RTECS: 9999999ZZ
BONDING & GROUNDING PROCEDURES. TRANSFER ONLY TO
RTECS: 9999999ZZ
INTERNALLY. KEEP OUT OF REACH OF CHILDREN. THIS
RTECS: 9999999ZZ
WHICH MAY BE PRESENT AT HAZARDOUS LEVELS ONLY DURING
RTECS: 9999999ZZ
DELIBERATELY CONCENTRATING & INHALING CONTENTS CAN BE
RTECS: 9999999ZZ
EXPOSURE LIMITS. REFER TO OSHA STANDARDS 1910.94,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:OVEREXPOS CAUSES EYE, SKIN &
RESP IRRIT. MAY CAUSE NERV SYS DEPRESS ACCOMPANIED BY HDCH, DIZZ,
NAUS, CONFUSN & STAG GAIT. EXTREME OVEREXPOS MAY RSLT IN UNCON &
POSS DEATH. CHRONIC:STUDIES HAVE A SSOC EXPOS TO CHROMIUM VI CMPDS
W/AN INCRD RISK OF RESP CANCER. PRLNGD OVEREXPOS TO INGREDS IN
INGRED (EFTS OF OVEREXP)
Explanation of Carcinogenicity:POTASSIUM ZINC CHROMATE: GROUP 1 (IARC);
KNOWN TO BE A CARCINOGEN (NTP); GROUP A1 (ACGIH)
Effects of Overexposure:HLTH HAZ:SECTION MAY CAUSE ADVERSE EFTS TO
LIVER, URINARY & RESPIRATORY SYSTEM. REPORTS HAVE ASSOCIATED
REPEATED & PROLONGED OVEREXPOSURE TO SOLVENTS W/PERMANENT BRAIN &
NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE BREATHING.
KEEP WARM & QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP &
WATER. REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE.
EYES:FLUSH W/LARG E AMOUNTS OF WATER FOR AT LEAST 15 MINS. GET MD.
Fire Fighting
Flash Point Method:PMCC
Flash Point:78.0F,25.6C
Lower Limits:0.9
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL & FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE
PREFERABLE. WATER MAY BE USED TO COOL (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATN TO HOT (SUPP DATA)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:CONTENTS ARE FLAMM. KEEP AWAY FROM
HEAT, SPARKS & OPEN FLAME. KEEP CONTR CLSD WHEN NOT IN USE. USE
ONLY W/ADEQ VENT. AVOID CONT W/SKIN & EYES.
Other Precautions:AVOID BRTHG VAP & SPRAY MIST. PROT AGAINST HAZ
DUST/FUMES WHICH MAY BE GENERATED BY SANDING, WIREBRUSHING,
ABRADING, BURNING, BRAZING OR WELDING OF DRIED FILM. DURING USE &
UNTIL ALL VAPS ARE GONE:KEE P AREA VENTD. DO NOT SMOKE. (SUPP DATA)
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR NIOSH/MSHA APPROVED
RESPIRATORY DEVICE FOR PROTECTION AGAINST MATERIALS IN INGREDIENT
SECTION.
Ventilation:LOC EXHST PREFERABLE. GEN EXHST ACCEPTABLE IF EXPOS TO
MATLS IN INGRED SECTION IS MAINTAINED BELOW APPLIC (ING 9)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:CLSD CONTRS TO PVNT PRESS BUILD-UP & POSS
AUTOIGNITION/EXPLOS WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ:SURF
REQS SPEC PRECS. DURING EMER CNDTNS OVEREXPOS TO DECOMP PRODS MAY
CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT. OBTAIN MED ATTN.
OTHER PREC:EXTING ALL FLAMES, PILOT LIGHTS & HEATERS. (ING 4)
Chemical Properties
Boiling Pt:B.P. Text:>240F,>116C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.11
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:63
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE: CO*2, CO & OXIDES OF METALS
IN INGREDIENTS.
Disposal
Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER RCRA
49CFR261. WASTE MUST BE TESTED FOR IGNIT/EXTRACTABILITY TO DETERM
APPLIC EPA HAZ WASTE NOS. INCIN IN APPRVD FACILITY. DO NOT INCIN
CLSD CONTR. DISP OF I/A/W FED, STATE & LOC REGS REGARDING
POLLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.